State Industries Water Heater Commercial Electric Water Heater User Manual |
C O M M E R C I A L
™
PATRIOT
LIGHT-DUTY
COMMERCIAL ELECTRIC WATER HEATERS
Designed for use as recovery heaters for
light-duty hot water supply service.
Patriot PCE water heaters are available
with tank capacities from 6 through 119
gallons. They can be installed for non-
simultaneous and single element operation
(maximum input up to 6 KW), or for
simultaneous dual-element operation
(maximum input up to 12 KW).
• Manual reset high temperature cutoff
per element (dual-element models)
™
• Factory wired for non-simultaneous
operation; easily converted to simulta-
neous operation
Glass-Lined Tank with
Anode Rod
• Provides long-lasting protection against
corrosion
Zinc-Plated Copper Sheath
Heating Elements Standard
Maximum Hydrostatic Working
Pressure: 150 psi
• Medium watt density design disperses
element temperature over larger
surface contact area to minimize scale
buildup, maximize efficiency and pro-
long element life
Meets or exceeds the thermal
efficiency and/or standby loss
requirements of the U.S.
Department of Energy and current
edition of ASHRAE/IESNA 90.1
• Element options from 1.5 KW to 6
KW (non-simultaneous or simultane-
ous operation), recoveries from 6 gph
to 49 gph at 100°F rise
Other Patriot™ PCE
Series Features
Standard Voltages for
Easy Installation
• Simplified, color-coded circuitry for
ease of service
• 120V, 277V single-phase, and 208V,
240V and 480V unbalanced 3-phase
delta
• Bonderized undercoat on cabinet with
baked enamel finish
• Top inlet and outlet openings
• Foam insulation
• Easily converted to single-phase at ter-
minal block (except for 208V with
6000 watt elements
• Drain valve
• Single-element heater, single-phase only
(see chart for dual-element options)
• UL-approved field conversion program
Factory-Installed
Terminal Block
Three-Year Limited Tank
Warranty
• Provides electrical service to heater and
connects to block
• Consult written warranty shipped with
water heater, or contact State for
complete information
Factory-Wired Controls
• Temperature control (adjustable from
110°F to 170°F on single-element;
120°F to 180°F on dual-element models)
For more information on State® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
SCESS00106
August 2008R
Page 1 of 4
©2007 State Water Heaters Company
TOP VIEW
PCE 6 10MSA, PCE 10 10MSA
PCE 17 10MSA, PCE 20 10MSA
ALTERNATE OUTLET
OUTLET
3/4" (FEMALE) NPT
3/4"(FEMALE)
NPT*
3/4" NPT
RELIEF VALVE
OPENING
A
B
C
ELECTRICAL
CONNECTION
INLET
3/4" (FEMALE)
NPT
FRONT VIEW
PCE 6 10MSA, PCE 10 10MSA
PCE 17 10MSA, PCE 20 10MSA
OUTLET
3/4" (FEMALE)
NPT
OUTLET
3/4" (FEMALE)
NPT
INLET
3/4" (FEMALE)
NPT
INLET
3/4" (FEMALE)
NPT
“D”
“D”
3/4" NPT
RELIEF VALVE
OPENING
2 1/2"
JUNCTION
BOX
JUNCTION
BOX
2 1/2"
TOP VIEW
PCE 30 20LSA, PCE 40 20LSA,
PCE 50 20LSA
TOP VIEW
“B”
“B”
3/4" NPT
RELIEF VALVE
OPENING
“A”
“A”
“C”
DRAIN
VALVE
BRASS
DRAIN
VALVE
3 3/4"
3 3/4"
FRONT VIEW
PCE 30 20RTA – PCE 120 20RTA
FRONT VIEW
PCE 30 20LSA, PCE 40 20LSA,
PCE 50 20LSA
Page 3 of 4
©2008 State Water Heaters Company
SCESS00106
August 2008R
C O M M E R C I A L
SUGGESTED SPECIFICATION
The water heater(s) shall be State Patriot™ Model(s) ________, rated at _______ KW, _______ volts, _______ -phase, 60
cycle AC. Water heater(s) shall be listed by Underwriters Laboratories and meet or exceed the thermal efficiency and/or standby
loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 shall be ________ gallon
capacity with a recovery capacity of ______ GPH at a temperature rise of ______°F with ______/______ upper/lower element
wattage. Heater(s) shall have 150 psi working pressure and be equipped with extruded high-density anode rod. All internal
surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition that has been fused to
steel by firing at a temperature of 1600°F. Electric heating elements shall be medium watt density with zinc-plated copper sheath
or Incoloy sheath _______________.
Each element shall be controlled by an individually mounted thermostat and high-temperature cutoff switch. The outer jacket
shall be a baked enamel finish and provided with a full-size control compartment for performance of service and maintenance
through a hinged front panel and shall enclose the tank with foam insulation.
Electrical junction box with heavy-duty terminal block shall be provided (except on 120V and 277V [no junction box on
PCE 6 10MSA thru PCE 20 10 MSA]). The drain valve shall be located in the front for ease of servicing. Heater tank shall
have a 3-year limited warranty as outlined in the written warranty. Fully illustrated instruction manual will be included.
For more information on State® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
Page 4 of 4
©2008 State Water Heaters Company
SCESS00106
August 2008R
|
Shark Iron GI465 User Manual
Sharp Cash Register XEA 201 User Manual
Sonance Speaker A800D User Manual
Sony Camcorder 4 124 311 121 User Manual
Sony Home Theater System 4 178 247 141 User Manual
Sony Stereo Amplifier TA FB730R User Manual
Sony VCR SLV SE800G User Manual
StarTechcom Computer Drive PEXSAT34 User Manual
Sterling Home Theater Server 88200025400 User Manual
Sunrise Medical Mobility Aid nonee User Manual